Consider the following statements regarding Built-up Columns 1. Lacings and battens are used to hold the individual components of a built-up column together so they act as a single unit. 2. Lacing bars are designed to resist a transverse shear force equal to 2.5% of the axial load on the column. 3. Battened columns are generally more efficient than laced columns for carrying very heavy eccentric loads. Which of the statements given above are correct?
- A1 and 2 onlyCorrect
- B2 and 3 only
- C1 and 3 only
- D1, 2 and 3
Solution
Concept
Built-up Columns (Lacing and Battening)
Formula
V = 0.025 P (Transverse Shear Force V = 2.5% of Axial Load P)
Step-by-step solution
1. Review the given statements regarding built-up columns. 2. Recall that lacings/battens unify column components (Statement 1 is correct) and lacing system design requires resisting a transverse shear force of 2.5% of the axial load, V = 0.025 P (Statement 2 is correct). 3. Note that laced columns handle heavy eccentric loads better than battened columns (Statement 3 is incorrect). 4. Select Option (a) "1 and 2 only" as the correct answer.
Explanation
Statements 1 and 2 are correct because lacings and battens connect individual steel sections to make them function as a single solid column, and lacing bars are designed for a standard transverse shear force of 2.5% of the column's total axial load. Statement 3 is incorrect because battened columns are not suitable for heavy eccentric loads or bending moments, whereas laced columns provide better triangulation and performance under such conditions. Therefore, option A ("1 and 2 only") is the correct answer.
Shortcut
To remember key rules for Built-up Columns, use the memory rule "2.5% Shear & Laced for Heavy": - 2.5% Shear: Lacing bars are always designed to resist a transverse shear force of 2.5% of the total axial load. - Laced > Battened: Laced columns handle heavy eccentric loads/moments due to diagonal triangulation, whereas battened columns are best only for purely axial loads.
Common mistake
A common mistake is selecting Option D (1, 2 and 3) by incorrectly assuming that battened columns are more efficient for heavy eccentric loads. In reality, battened columns should only be used for axially loaded columns without significant eccentricities or moments, while laced columns are much better suited for heavy eccentric loads due to their diagonal triangulation.
Correct answer: A) 1 and 2 only